| Sign In | Join Free | My lightneasy.org |
|
Price : USD 397/Unit
Packaging Details : original packing
Process Connection / Installation : 1/2-20 UNF, 6-Pin Connector, 6-Inch Rigid Stem with 18-Inch Flexible Section
Pressure Range : 0 to 700 bar
Brand : Gefran
Model Number : ME1-6-M-B07C-1-4-D 2130X000X00
Ordering Requirement : Verify F007714, 700 bar controller scaling, loop wiring, stem lengths and full nameplate
Supply Ability : 2 Units per Month
Product Type : High-Range Melt Pressure Transmitter
Output / Accuracy Class : 4–20 mA / 0.5% FSO
Payment Terms : T/T
Series / Control Platform : ME1 Series / Mercury Filled
Delivery Time : 7-14 Days
Model : ME1-6-M-B07C-1-4-D 2130X000X00
MOQ : 1 unit
Place of Origin : USA
Brand Name : Gefran
The Gefran ME1-6-M-B07C-1-4-D 2130X000X00, ordering code F007714, is a high-range melt pressure transmitter calibrated from 0 to 700 bar. It is intended for pressure monitoring in extrusion systems where the expected operating and protective limits exceed the capacity of common 350 or 500 bar transmitters. The transmitter supplies a two-wire 4–20 mA signal and requires a compatible 10–30 VDC current loop.
| Complete Model | ME1-6-M-B07C-1-4-D 2130X000X00 |
| Ordering Code | F007714 |
| Pressure Range | 0 to 700 bar |
| Output Signal | 4–20 mA |
| Supply Voltage | 10–30 VDC |
| Accuracy | Less than ±0.5% FSO |
| Response Time | Approximately 1 ms |
| Process Connection | 1/2-20 UNF |
| Stem Configuration | 153 mm rigid plus 457 mm flexible |
| Protection | IP65 with the correct mating connector |
This model can serve high-pressure melt locations such as melt-pump discharge, restrictive filtration sections and extrusion dies, provided that the machine design permits a 700 bar measuring range. The control system should interpret 4 mA as zero and 20 mA as 700 bar. Using an incorrectly configured analog scale can conceal an overpressure condition or cause nuisance shutdowns.
Before removing the installed transmitter, record the engineering units, full-scale setting, alarm thresholds and shutdown logic. Seven hundred bar is approximately 10,153 psi and is therefore not the same calibration as a 10,000 psi P10M model. Inspect the pressure port for contamination and confirm that the sensing diaphragm will not contact the bottom of the mounting hole. Maintain the flexible section above its minimum safe bend radius and protect the connector from moisture and polymer residue.
ME1-6-M-P10M-1-4-D F007744 is calibrated to exactly 10,000 psi rather than 700 bar. ME1-6-M-B05C-1-4-D F007704 is the lower 500 bar version. ME2-6-M-B07C-1-5-D F007779 adds a type J thermocouple and uses a longer rigid-stem code. ME1-6-H-B07C-1-4-D F044832 changes the accuracy class from M to H. Related models are provided for family reference only and are not automatically interchangeable.
State F007714 and the complete 2130X000X00 model when requesting supply. Confirm the 700 bar calibration, six-pin connector, 4–20 mA output, process thread, mechanical lengths and nameplate condition. Suggested pricing does not establish current inventory or delivery time.
|
|
Gefran ME1-6-M-B07C-1-4-D Melt Pressure Transmitter 700 Bar Images |